πŸ“ Miami, Hialeah, Doral, Miami Lakes & More  | πŸ“ž (786) 587-0722  |  Mon–Sun 6:00 AM – 10:00 PM
Services
🌬️ Dryer Repair🫧 Washer Repair 🧊 Refrigerator Repair🍽️ Dishwasher Repair πŸ”₯ Oven & Stove RepairπŸ“‘ Microwave Repair πŸ—‘οΈ Garbage DisposalπŸ’¨ Dryer Vent Cleaning
Service Areas
πŸ“ AventuraπŸ“ Bal Harbour πŸ“ Bay Harbor IslandsπŸ“ Biscayne Park πŸ“ BrownsvilleπŸ“ Coral Gables πŸ“ Coral TerraceπŸ“ Country Club πŸ“ DoralπŸ“ El Portal πŸ“ FlagamiπŸ“ Fontainebleau πŸ“ GladeviewπŸ“ Golden Beach πŸ“ HialeahπŸ“ Hialeah Gardens πŸ“ Indian CreekπŸ“ Ives Estates πŸ“ KendallπŸ“ Key Biscayne πŸ“ MedleyπŸ“ Miami πŸ“ Miami BeachπŸ“ Miami Gardens πŸ“ Miami LakesπŸ“ Miami Shores πŸ“ Miami SpringsπŸ“ North Bay Village πŸ“ North MiamiπŸ“ North Miami Beach πŸ“ Opa-lockaπŸ“ Palmetto Bay πŸ“ PinecrestπŸ“ South Miami πŸ“ Sunny Isles BeachπŸ“ Surfside πŸ“ SweetwaterπŸ“ Virginia Gardens πŸ“ Westchester
Brands
🏷️ Amana🏷️ Bosch 🏷️ Electrolux🏷️ Fisher & Paykel 🏷️ Frigidaire🏷️ GE 🏷️ Kenmore🏷️ KitchenAid 🏷️ LG🏷️ Maytag 🏷️ Miele🏷️ Samsung 🏷️ Sub-Zero🏷️ Thermador 🏷️ Viking🏷️ Whirlpool 🏷️ Wolf
⚑ Error CodesπŸ“ Blog ❓ FAQ🏠 Aboutβœ‰οΈ Contact
πŸ“ž Call (786) 587-0722

LG Dryer Error Codes

Complete fault code reference for LG dryers. Each code includes probable causes and verified diagnostic steps based on manufacturer service documentation.

πŸ“‹ 6 Fault Codes
🌬️ LG Dryer
πŸ“ž Same-Day Service Available

Found Your Error Code?

Our technicians serve Miami, Hialeah, Doral, and surrounding areas β€” same day. Call now for fast diagnosis and repair.

πŸ“ž Call (786) 587-0722
πŸ“‹ Error Code Index β€” LG Dryer
d80
Restricted Airflow 80%
Dryer airflow is 80% restricted β€” lint screen or vent partially blocked.
High Priority
Possible Causes
  • Lint screen heavily clogged with buildup
  • Exhaust vent duct partially blocked
  • Exterior vent flap partially stuck closed
Diagnostic Steps
  1. 1Clean lint screen thoroughly
  2. 2Inspect full exhaust duct run for blockage
  3. 3Check exterior vent flap opens freely
d90
Restricted Airflow 90%
Dryer airflow is 90% restricted β€” severe vent blockage detected.
Urgent
Possible Causes
  • Exhaust vent duct severely blocked
  • Lint screen completely clogged
  • Vent duct crushed or kinked
Diagnostic Steps
  1. 1Stop dryer immediately β€” fire risk
  2. 2Clean lint screen and inspect full exhaust duct
  3. 3Replace any crushed or kinked duct sections
d95
Restricted Airflow 95%
Dryer airflow is 95% restricted β€” dryer should not be operated.
Urgent
Possible Causes
  • Exhaust vent duct completely blocked
  • Exterior vent sealed shut
  • Duct disconnected β€” exhausting into wall cavity
Diagnostic Steps
  1. 1Stop dryer immediately β€” do not operate
  2. 2Inspect and clear full exhaust path
  3. 3Verify exterior vent is clear and unobstructed
E13
Outlet Thermistor Fault
Exhaust air temperature thermistor open or out of expected range.
Medium Priority
Possible Causes
  • Thermistor failed open or shorted
  • Connector loose or corroded
Diagnostic Steps
  1. 1Inspect connector for corrosion
  2. 2Test thermistor resistance β€” should decrease as temperature rises
  3. 3Replace thermistor if reading is OL or near zero
E31
Drive Motor Fault
Drive motor not starting or stalling during operation.
High Priority
Possible Causes
  • Drive motor failed or seized
  • Drive belt broken or dislodged
  • Motor capacitor failed
Diagnostic Steps
  1. 1Check drive belt for breakage
  2. 2Test motor capacitor
  3. 3Test motor winding continuity β€” replace if open circuit
HS
High Humidity Sensor Fault
Humidity sensor reading outside expected range during cycle.
Medium Priority
Possible Causes
  • Humidity sensor failed
  • Sensor connector loose or corroded
  • Sensor contaminated with detergent residue
Diagnostic Steps
  1. 1Inspect sensor and connector for corrosion or residue
  2. 2Clean sensor surface if contaminated
  3. 3Replace humidity sensor if reading out of range

Need a Technician in Miami or Hialeah?

AppliancesCare provides same-day LG dryer repair across Miami-Dade. Bilingual service β€” English & Spanish.

πŸ“ž Call (786) 587-0722

Important Notice: Error code information on this page is based on LG manufacturer service documentation. Dryer repair involves high-voltage components and hot surfaces. Always disconnect power before servicing. AppliancesCare Appliance Repair LLC provides this information for educational purposes only.