πŸ“ AventuraπŸ“ Bal Harbour πŸ“ Bay Harbor IslandsπŸ“ Biscayne Park πŸ“ BrownsvilleπŸ“ Coral Gables πŸ“ Coral TerraceπŸ“ Country Club πŸ“ DoralπŸ“ El Portal πŸ“ FlagamiπŸ“ Fontainebleau πŸ“ GladeviewπŸ“ Golden Beach πŸ“ HialeahπŸ“ Hialeah Gardens πŸ“ Indian CreekπŸ“ Ives Estates πŸ“ KendallπŸ“ Key Biscayne πŸ“ MedleyπŸ“ Miami πŸ“ Miami BeachπŸ“ Miami Gardens πŸ“ Miami LakesπŸ“ Miami Shores πŸ“ Miami SpringsπŸ“ North Bay Village πŸ“ North MiamiπŸ“ North Miami Beach πŸ“ Opa-lockaπŸ“ Palmetto Bay πŸ“ PinecrestπŸ“ South Miami πŸ“ Sunny Isles BeachπŸ“ Surfside πŸ“ SweetwaterπŸ“ Virginia Gardens πŸ“ Westchester
Brands
🏷️ Amana🏷️ Bosch 🏷️ Electrolux🏷️ Fisher & Paykel 🏷️ Frigidaire🏷️ GE 🏷️ Kenmore🏷️ KitchenAid 🏷️ LG🏷️ Maytag 🏷️ Miele🏷️ Samsung 🏷️ Sub-Zero🏷️ Thermador 🏷️ Viking🏷️ Whirlpool 🏷️ Wolf
⚑ Error CodesπŸ“ Blog ❓ FAQ🏠 Aboutβœ‰οΈ Contact
πŸ“ž Call (786) 587-0722

Frigidaire Oven & Stove Error Codes

Complete fault code reference for Frigidaire oven & stoves. Each code includes probable causes and verified diagnostic steps based on manufacturer service documentation.

πŸ“‹ 7 Fault Codes
πŸ”₯ Frigidaire Oven & Stove
πŸ“ž Same-Day Service Available

Found Your Error Code?

Our technicians serve Miami, Hialeah, Doral, and surrounding areas β€” same day. Call now for fast diagnosis and repair.

πŸ“ž Call (786) 587-0722
πŸ“‹ Error Code Index β€” Frigidaire Oven & Stove
F10
Temperature Runaway
Oven temperature exceeded maximum safe limit β€” uncontrolled heating.
Urgent
Possible Causes
  • Temperature sensor shorted β€” sending false low reading
  • Control board relay welded closed β€” heater running unregulated
Diagnostic Steps
  1. 1Disconnect power immediately
  2. 2Test temperature sensor β€” near 0Ξ© confirms short
  3. 3Replace sensor and verify relay before returning to service
F11
Stuck Key / Shorted Keypad
A key on the membrane panel is continuously activated.
Medium Priority
Possible Causes
  • Moisture on keypad causing false activation
  • Physical damage to membrane keypad
  • Debris under keypad surface
Diagnostic Steps
  1. 1Dry keypad area with clean cloth
  2. 2Press Cancel to reset
  3. 3Disconnect power 60 seconds
  4. 4Replace control panel if fault persists
F30
Low Voltage
Control board detecting low supply voltage.
Medium Priority
Possible Causes
  • Household voltage below rated minimum
  • Loose connection at terminal block
  • Circuit breaker partially tripped
Diagnostic Steps
  1. 1Check circuit breaker β€” reset if tripped
  2. 2Verify terminal block connections are tight
  3. 3Contact electrician if supply voltage is confirmed low
F31
High Voltage
Control board detecting high supply voltage.
High Priority
Possible Causes
  • Utility supply voltage elevated above rated maximum
  • Neutral wire loose β€” causing voltage imbalance
Diagnostic Steps
  1. 1Contact utility company if supply voltage is confirmed high
  2. 2Check neutral connection at service panel
  3. 3Do not operate appliance until voltage is within rated range
F3
Temperature Sensor Open
RTD probe open circuit β€” oven cannot monitor temperature.
Medium Priority
Possible Causes
  • RTD probe failed open internally
  • Connector loose or corroded
  • Probe wiring open
Diagnostic Steps
  1. 1Test probe resistance β€” ~1080Ξ© at room temperature
  2. 2OL reading confirms failed probe
  3. 3Reseat connector before replacing
  4. 4Replace sensor if open confirmed
F4
Temperature Sensor Short
RTD probe shorted β€” control receiving incorrect temperature reading.
Urgent
Possible Causes
  • RTD probe failed shorted
  • Probe wiring touching oven cavity metal
Diagnostic Steps
  1. 1Test probe β€” near 0Ξ© confirms short
  2. 2Inspect probe wiring
  3. 3Replace sensor β€” do not operate until repaired
F8
Door Lock Fault
Door lock not confirming position during self-clean cycle.
Medium Priority
Possible Causes
  • Lock motor failed
  • Mechanical obstruction in latch path
  • Wiring to lock assembly open
Diagnostic Steps
  1. 1Check latch for obstruction
  2. 2Test lock motor continuity
  3. 3Replace lock assembly if motor failed

Need a Technician in Miami or Hialeah?

AppliancesCare provides same-day Frigidaire oven & stove repair across Miami-Dade. Bilingual service β€” English & Spanish.

πŸ“ž Call (786) 587-0722

Important Notice: Error code information on this page is based on Frigidaire manufacturer service documentation. Oven repair involves high-voltage components. Gas appliances require licensed gas technician service. AppliancesCare Appliance Repair LLC provides this information for educational purposes only.